ADR View

Outil de modélisation et quantification des réserves d’ampacité

sur base d’historiques de données météorologiques

DÉCOUVRIR CETTE SOLUTION

ADR Sense

Capteur de vibrations auto-alimenté avec communication GSM

DÉCOUVRIR CETTE SOLUTION

ADR Operate

Outil d’acquisition de données et de calcul d’ampacité en temps réel

DÉCOUVRIR CETTE SOLUTION

ADR Trend

Outil de prévision d’ampacité de 1 à 4 heures

DÉCOUVRIR CETTE SOLUTION

ADR Horizon

Outil de prévision d’ampacité à 60h sur base de prévisions météorologiques

DÉCOUVRIR CETTE SOLUTION

ADR Sense-D 2017-02-21T09:18:20+00:00

NOS SOLUTIONS

ADR Sense-D

DLR monitoring sensor for Distribution grids

A sensor monitoring Dynamic Line Rating in real time for Distribution over-head power lines (up to 130kV).

The patented sensing method used by ADR- Sense-D derives from the one used for more than 10 years by ADR-Sense, the leading Transmission monitoring sensor used by many TSOs.

It relies on a patented sensing method using low frequency mechanical vibrations of the line (induced by wind, thermal convection) and use them to compute the sag of the line.

ADR-Sense-D’s principle relies on the direct relationship linking the fundamental vibration frequency of a conductor to its sag.

Therefore, no calibration, no conductor data, no conductor model required, an accurate sag measurement is guaranteed, ensuring a safe and secure operation of the grid at all times.

ADR Sense’s other key feature is that, besides the temperature and the current, it measures wind speed exactly where it matters: on the conductor itself.

The wind is indeed the most influential parameter in determining the ampacity (all other parameters being constant, the ampacity doubles when wind speed increases from 0.5m/s to 5m/s).

ADR-Sense-D is designed specifically for distribution overhead lines and features in particular:

  • a light weight, to avoid inducing mechanical stress on small conductors
  • suitable for a large range of conductor cross sections
  • a large range, self-powered electronics, enabling the sensor to operate without batteries, therefore avoiding maintenance.
  • Ease of installation: can be installed from the ground, even on live lines, 10mn installation time: sensors can easily be moved to different lines if needed

Besides the sag and wind speed required for DLR, ADR-Sense-D also monitors the electrical load (current) and the temperature.

ADR-Sense-D allows DSOs to:

  • easily integrate more Renewables, in particular Wind Generation, thanks to the strong correlation between increased thermal ratings of lines cooled down by wind.
  • maximize the use of existing assets in full safety, giving DSOs another tool to optimize Capex.
  • monitor key parameters of critical lines, in a fully integrated solution, enabling to move to a real «smart grid».

ADR-Sense-D is a part of the ADR product family, which offers a complete hardware and software suite of products to actively monitor lines for Dynamic Line Rating applications, fully SCADA-integrated, including forecasting capabilities.

RELATED CASE STUDIES

Intégration des énergies renouvelables dans le réseau
• Optimisation des lignes existantes dans le cadre de travaux de maintenance programmée
Gestion des pics de consommation été / hiver

RELATED PRODUCTS

ADR Sense
ADR View
ADR Operate
ADR Trend
ADR Horizon

BACK TO SOLUTIONS
Latest news

Pour la troisième année consécutive, Ampacimon est nominé dans le Top 50 Deloitte

octobre 25th, 2018|0 Comments

Ampacimon est nominé dans le Top 50 Deloitte des sociétés technologiques à croissance rapide. Ce cla [...]

Ampacimon signed a new partnership agreement with Madrid-based company DIAEL

septembre 17th, 2018|0 Comments

Ampacimon signed a new partnership agreement with Madrid-based company DIAEL, an innovative supplier [...]

Ampacimon signed important partnership agreement with Netherlands based company Energy Solutions (ENSOL)

septembre 17th, 2018|0 Comments

Ampacimon signed important partnership agreement with Netherlands based company Energy Solutions (EN [...]